. A complete Parts List is available at www.HobartWelders.com
OM-243 712 Page 13
SECTION 5 − INSTALLATION
5-1. Selecting A Location
! Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
! Do not move or operate unit
where it could tip.
1 Grounded Receptacle
Locate unit near correct input
power supply.
803 443-C
18 in.
(460 mm)
18 in.
(460 mm)
1
2
5-2. Installing Work Clamp
1 Nut
2 Work Cable From Unit
3 Work Clamp
4 Screw
5 Work Clamp Tabs
Bend tabs around work cable.
6 Insulator Grip
Slide one insulating grip over work
cable before connecting to clamp.
Slide insulating grips over handles.
Ref. 802 456
. Connection hardware must be tightened with proper tools. Do not just
hand tighten hardware. A loose electrical connection will cause poor
weld performance and excessive heating of the work clamp.
1
2
3
4
5
Tools Needed:
7/16 in.
6
7/16 in.
5-3. Process/Polarity Table
Process Polarity
Cable Connections
Cable To Gun Cable To Work Clamp
FCAW − Self-shielding wire − no
shielding gas
DCEN − Straight Polarity Connect to negative (−) output
terminal
Connect to positive (+) output terminal
GMAW − Solid wire with shielding gas DCEP − Reverse Polarity Connect to positive (+) output
terminal
Connect to negative (−) output terminal
5-4. Changing Polarity
1 Lead Connections For Direct
Current Electrode Negative
(DCEN)
2 Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended po-
larity, and see Section 5-3.
Close door.
Ref. 210 428
1 2